In semiconductor reliability testing, a cold-start check asks whether a sensor interface IC meets its output offset limit when its first reading is due. A steady-state check asks whether that same IC stays within its limit after the powered package has stabilized. A SANWOOD Temperature Forcing System directs controlled air to the package while external instruments power the board and capture its output.
In semiconductor reliability testing, a cold-start check asks whether a sensor interface IC meets its output offset limit when its first reading is due. A steady-state check asks whether that same IC stays within its limit after the powered package has stabilized. A SANWOOD Temperature Forcing System directs controlled air to the package while external instruments power the board and capture its output. For a cold-start check, bring the unpowered IC to the specified starting temperature. Capture the output from the event defined in the device specification, such as a supply-threshold crossing or an enable edge. Apply the offset limit when the output is required to be valid. For a steady-state check, take the reading once the powered package satisfies the temperature tolerance and stability interval in the test plan.
Consider an automotive sensor interface IC with an analog output. Use the input condition that the device specification defines for its offset test, such as zero differential input. Keep the supply, reference voltage and output load consistent with the test definition. At each test point, record the difference between the measured output voltage and the specified nominal output, using the sign convention in the device specification.
Start with the point at which the device specification says the output must be valid. If the device is allowed time to settle after power-on, the acquisition should still capture that interval. The trace shows how the output arrived at its first valid value. Apply the startup limit from the specified instant, using the trigger the specification defines. A supply crossing its operating threshold and an enable signal going high can be two different events on the same board.
Also check whether the limit applies to the offset at the cold test point or to the change from a room-temperature baseline. If the criterion is a change, retain the baseline for that individual device under the specified input, supply and load. A cold reading alone cannot establish how far that device has drifted.
Mark the trigger and the start of the output-valid window on the same electrical trace. Keep the signal leading up to that window visible. A peak during the permitted settling interval can help explain how the circuit starts up. Assess it against any limit specified for settling. Once the output must be valid, apply the offset limit and any duration rule stated for that window.
For the steady-state check, mark where the powered package first satisfies the test plan’s stability criterion and identify the electrical reading taken under that condition. If the output crossed the applicable limit during startup and recovered by the cold hold, retain both findings under their respective criteria. If acquisition began after the powered package stabilized, report the steady-state offset and mark cold startup as unmeasured. Record the trigger and acquisition window for each device so the result can be reviewed against the applicable limit. To assess a brief excursion, the electrical instrument needs the bandwidth, sampling interval and acquisition window required to resolve it.
The SANWOOD Temperature Forcing System offers Air Mode for control of the delivered air and DUT Mode for control using temperature feedback from the device under test. It accepts external Type T and Type K thermocouples. For a test defined at the package surface, identify the attachment point on a fixture drawing. A thermocouple at the top of the package measures that location. A junction-temperature requirement calls for a suitable junction measurement or a validated estimate.
Keep the temperature record running through power-on. Once the IC draws current, heat flows into the package and board, and the package temperature can move even while the air setpoint stays constant. For the startup result, retain the measured temperature immediately before the trigger and the electrical trace that follows. For the steady-state result, verify that the package meets the specified condition under operating load. Give both records the same device ID and a shared timing reference. If the excursion first appears when the workload changes later in the run, SANWOOD's guide to reproducing intermittent IC faults under load covers that sequence.
Check the setup with the probes installed. A lead routed across the thermal head opening can change airflow, and moving a probe to make room for the head can change the electrical measurement. A fixture drawing should show where the head, thermocouple and probes sit together. If the procedure requires the entire board and its reference circuitry to share a specified ambient condition, consider an environmental test chamber with room for the powered fixture. For questions about heat load and sample stabilization, see the SANWOOD Temperature Forcing System selection guide.
Yes, if the IC output depends on that reference. A local air stream can reach a neighboring component as well as the package under test. If the reference is in the airflow path, measure its voltage during the same startup sequence. A change in both signals warrants a closer look at the reference circuit before attributing the shift to the IC.
Check where room air can enter around the probe leads or socket. Compare the dew point of the air at the fixture with the temperature of exposed cold surfaces. Depending on the openings and operating conditions, a shroud or dry-air purge may be appropriate. Include the probe routing when reviewing moisture control with SANWOOD.
The device count stays the same. Repeating the startup sequence can show whether a symptom recurs on that IC. Record the device ID, the number of attempts and the starting condition for each run. Report the number of distinct devices separately so a reviewer can see how broadly the result applies.
Send the package dimensions, target temperature and tolerance, expected power dissipation and a drawing of the populated fixture. Mark the temperature measurement point and the probe points needed to observe enable and output. Include the earliest time the output must be valid after power-on and the rule for starting the steady-state reading. With those details, SANWOOD can review whether the proposed thermal head placement gives the package the required exposure while leaving both signals accessible. Contact info@sanwood.com.