Thermal Shock Testing: How to Investigate IC Cold-Start Failures

​In semiconductor reliability testing, a Thermal Shock Chamber exposes IC packages to specified hot and cold conditions, while a Temperature Forcing System directs controlled airflow to a device area for temperature-dependent electrical checks. If an IC passes its room-temperature retest after thermal shock testing but intermittently fails to start when cold, preserve the exposure record and reproduce the symptom at a measured package temperature. A post-shock cold failure alone does not establish that thermal shock caused it.

Thermal Shock Testing: How to Investigate IC Cold-Start Failures

What Is Thermal Shock Testing, and Why Test ICs?

Thermal shock testing subjects samples to rapid changes between specified hot and cold conditions. The applicable method defines the exposure medium, temperature limits, transition requirements, dwell periods and cycle count. Within an IC package, the silicon die, substrate and other materials expand and contract at different rates. Repeated exposure can stress interfaces and interconnects. Qualification teams use the prescribed method to evaluate the package against the requirements of their test plan.

Consider a hypothetical diagnostic scenario: an IC completes its required exposure and passes the room-temperature electrical retest. During a subsequent low-temperature check, it starts successfully on some attempts but fails on others. This calls for a repeatable cold-start measurement and a review of the available baseline—not an immediate conclusion about package damage.


Connect the SANWOOD Thermal Shock Chamber Run to the Device

For plans specifying air-to-air exposure, theSANWOOD Thermal Shock Chamber series includes moving-carrier and stationary-sample configurations. Select the arrangement around the packages, fixtures and any attached temperature leads.

Selection parameterTwo-zone configurationThree-zone configuration
Exposure mechanismA carrier moves samples between hot and cold zones.Samples remain stationary while dampers switch the airflow path.
Published shock-temperature options−65°C to +150°C−65°C to +150°C
Setup to reviewCarrier load, sample retention and lead movement Fixture position, package spacing and airflow access
Evidence for the runTemperature records linked to carrier transferTemperature records linked to airflow switching

These ranges describe catalog options, not a single configuration. Confirm the selected equipment and its loaded performance against the required test sequence. TheIC package thermal shock testing guide explains transfer, switching and temperature recovery in more detail.

For the device under investigation, retain its ID, chamber-run reference, fixture position where recorded, temperature traces, recovery conditions and electrical readout time. Keep required qualification results separate from any supplemental cold checks added to investigate the symptom. This distinction makes clear which requirements were tested and which questions remain open.


Reproduce the Cold Start With a SANWOOD Temperature Forcing System

A SANWOOD Temperature Forcing System, also called a thermal air stream system, delivers temperature-controlled airflow through a thermal head to a selected device area. External electrical instruments supply power, execute the startup sequence and measure the response.

First define the event to reproduce. Starting an unpowered device after it reaches the cold condition is different from cooling a device that is already running. Use the sequence associated with the reported symptom.

ParameterPublished SANWOOD configurationRelevance to the cold retest
Air temperature range−80°C to +225°CVerify the required temperature at the chosen package measurement point.
Typical air transition Approximately 10 seconds between −55°C and +125°C, in either direction Establish package stabilization separately before the electrical check.
Output airflow 4–18 scfmReview coverage with the fixture, thermal cap and leads in place.
Control modesAir Mode and DUT ModeChoose the required air or device-feedback reference.
External thermocouple inputsType T and Type KDefine the sensor attachment point and record temperature at startup.

These specifications apply to the published configuration; confirm the supplied configuration in the quotation. Air transition time does not establish the package stabilization time. A package-surface reading also does not, by itself, establish the IC junction temperature. Keep the air setpoint and measured package temperature as separate records.

With the thermal head in position, check access to power leads, signal connections and probes. Review clean, dry compressed-air requirements and moisture control around the cold socket and board. 

For a comparable before-and-after retest, use the same device, fixture and socket where practical. Keep the supply voltage, startup program, power-off interval, temperature measurement point and stabilization criterion consistent. Record any changes rather than treating the results as equivalent. Count unsuccessful starts against the total number of attempts; a single successful restart does not describe an intermittent symptom adequately.


What Can the Retest Results Establish?

The following example assumes a required room-temperature readout and a supplemental cold-start investigation. It is an illustrative scenario, not a customer test result.

Available comparisonWhat the evidence supports Next step
Room-temperature pass before and after exposure; no pre-exposure cold resultThe cold symptom was observed after exposure; its onset is undetermined.Document the cold condition and repeatability without assigning a cause.
Comparable cold-start pass before exposure and failure afterwardA change in cold-start behavior under the recorded conditions. Carry both records into failure analysis; the change alone does not identify the physical mechanism.
Symptom changes when the socket or board changes The setup affects the observed behavior. Investigate that effect before attributing the failure solely to the IC.

Preserve the original setup long enough to capture the symptom when practical, then change one variable at a time. Link each electrical result to the same device ID and the temperature at the relevant event. The useful output is a reproducible condition and a traceable comparison that the failure-analysis team can examine.


Define the Equipment Review With SANWOOD

SANWOOD has manufactured environmental test equipment since 1995. Its engineering support includes matching equipment configurations to sample dimensions, fixtures, temperature profiles and monitoring requirements. For this application, provide separate requirements for the two stages:

  • Thermal shock exposure: the prescribed sequence, package quantity, representative fixture load and measurement locations. Request the relevant loaded temperature records or agree on checks for equipment acceptance.

  • Cold electrical retest: the fixture drawing, target package temperature, sensor location, operating heat load, startup sequence and required electrical access. Review whether the proposed thermal-head arrangement can support those conditions during the measurement.

Send these details to SANWOOD to review the chamber configuration, the localized retest setup, or both. The equipment proposal should address the conditions your lab needs to establish and measure.


Frequently Asked Questions

Should we repeat thermal shock before troubleshooting the same IC?

Preserve the sample and its exposure history first. Another run adds stress and may change the condition under investigation. If repeated exposure is necessary, have the qualification owner and failure-analysis team agree on the sequence and whether separate samples are needed.

How can we match a temperature trace to an ATE failure log?

If the thermal system and automatic test equipment (ATE) log separately, use a common time reference or shared event marker. Check whether timestamp resolution is sufficient to associate the startup result with the package reading. Confirm any required trigger, interface or data-export function for the proposed equipment.

What if the failure appears only when the entire board is cold?

Use the full-board condition as the reference for reproducing the symptom. Localized airflow may then help investigate which area contributes to it. Record relevant board and device temperatures; a localized retest should not be assumed equivalent to whole-board exposure.